Brandt HS-3400 centrifuge is used to process unweighted and weighted, water-based and oil based drilling fluids(mud). Here we made a comparison between Brandt HS-3400 centrifuge and GNLW363VFD centrifuge.

What is the difference and specs in common?
Model | Brandt HS-3400FEVSD | GNLW363VFD centrifuge |
length | 124in(3150mm) | 117inch(2970mm) |
width | 69in(1753mm) | 59inch(1499mm) |
height | 59inch(1499mm) | 68inch(1727mm) |
Weight | 7606lb(3453kg) | 6613lb(3000kg) |
Bowl diameter | 14inch(356mm) | 14inch(356mm) |
Bowl length | 49.5in(1257mm) | 49.5in(1257mm) |
Maximum bowl speed | 4000rpm | 3900rpm |
Typecal bowl speed | 2900rpm | 2800rpm |
Max processing capacity | 200gal/min(757lit/min) | 176gal/min |
Drive type | Variable frequency drive(VFD) | Variable frequency drive(VFD) |
Max G-force | 3180 | 3000 |
Gear box ratio | 52:1 | 39:1 |
Gear box type | Two stage, planetary | Two stage, planetary |
Main drive motor | 40HP(30KW) | 40HP(30KW) |
Back drive motor | 25HP(19KW) | 10HP(7.5KW) |
Continue reading “Brandt HS-3400 centrifuge VS GNLW363VFD centrifuge”